Vessel media fill calculator

Pick a FlowShell FRP vessel (or enter custom dimensions) and a filter media; get the settled-bed fill in litres and kilograms, the bed depth, the freeboard the media needs for backwash expansion, and the backwash flow that vessel demands.

Results

Usable vessel volume~65 L
Media fill (settled bed)~50 L (77% of vessel volume) ≈ 80 kg
Bed depth at that fill~991 mm
Freeboard the media needs≥30% of bed depth (bed expands ~20%)
Backwash flow for this vessel1.87 m³/h (31 L/min) at 37 m/h

The fill is calculated by mass and settled volume, so fill to the weight, not to a line on the vessel. Support fine media on a graded gravel underbed unless the vessel has a false-bottom distributor (the bottom dome typically holds the gravel), and backwash new media to drain before first service. If the installation cannot deliver the backwash flow above, pick a smaller vessel or a media with a lower backwash demand.

Notes on this media

Clack quotes 37–49 m/h backwash for fine (0.45–0.55 mm) sand with 20% freeboard minimum, which matches conventional rapid-sand practice; the default here is the bottom of that band. Coarser and denser gradings need MORE upflow to fluidise, not less, and cold water needs less than warm for the same expansion — so confirm the rate against your actual grading and the coldest water the filter will see, then check the valve and the drain can pass it. DWT standard fills allow ~30% freeboard.

Spec sheet: FlowShell FRP1054-2.5 technical data sheet (PDF)

Parts for this selection

Typical catalogue parts for this vessel and media; the valve shown is the smallest that passes the backwash flow. The branch confirms the final kit against your service flow.

  • Pressure vessel

    FRP1054Fibreglass pressure vessel 10" x 54", 2.5" top opening (62.5 L)

    Ex-stock (0–3 days)Ex-stock
  • Control valve

    F67C1Runxin F67C1 automatic backwash filter valve, 2.5" tank thread, 4 m³/h

    Ex-stock (0–3 days)Ex-stock
  • Riser pipe

    RISER1.4Riser pipe 27 mm, 1.4 m, for 844, 1054 and 1354 vessels

    Ex-stock (0–3 days)Ex-stock
  • Bottom distributor

    DISTBOT27Bottom distributor for 27 mm riser

    Ex-stock (0–3 days)Ex-stock
  • Top distributor

    DISTTOP27Top distributor for 27 mm riser

    Ex-stock (0–3 days)Ex-stock
  • This media is not in the online catalogue yet: ask the branch to quote it with the vessel.

Formula used

V = [π/4 × d² × (h − d) + π/6 × d³] × 1000

fill = V × media fill fraction · rest = freeboard

bed depth ≈ fill ÷ 1000 ÷ A · A = π × d² ÷ 4

Qb = A × vb

V
usable vessel volume (shell + domes), L; the bracket is m³, ×1000 gives litres
d
vessel internal diameter, m
h
vessel overall height, m
A
bed cross-sectional area, m²
Qb
backwash flow the installation must deliver, m³/h
vb
design backwash velocity for the media, m/h

These are geometric estimates. Volume assumes a plain cylinder with hemispherical ends on the nominal overall height, and bed depth divides that volume by the cylinder area, so it ignores the dome the bed actually sits in; neither accounts for the distributor, riser and support gravel that displace media. Final fills come from the manufacturer capacity figure and the real available expansion height. Vessel dimensions are nominal trade designations; FlowShell figures follow DWT's published spec sheets (DWT-DS-I-001 to -010). Fill fractions, freeboard, expansion, backwash velocities and densities are per-media design values from the manufacturers' data sheets (Clack, Dryden Aqua, DMI-65, Watch Water, Rotocarb, Calgon, Jacobi, Purolite, Extrepure, Inversand, DWT). Always confirm against the specific media's datasheet, and note that Siliphos-type dosing media do not belong in a backwashed vessel bed at all.

The background

Equipment for this duty

Send the water analysis and duty point, and the branch confirms exact selections, pricing and lead times, usually within one working day.

Request a quote

Results are indicative engineering estimates based on standard formulas and typical assumptions. They are not a design service; confirm any design against a full water analysis and the relevant manufacturer’s data.